Overview
GE IS215UCVDH5AN is a dual-slot processor controller board. This board is the "brain" of large rotating machinery control systems. It executes control algorithms, processes sensor input, and outputs control commands to regulate fuel, air intake, and other actuators.
It is part of the Mark VI series. Note: The IS215UCVDH5AN utilizes a dual-slot configuration and must be installed in designated slots in a chassis or rack. All associated equipment must be completely shut down before installation.
🚀Function & Features
- The GE IS215UCVDH5AN is equipped with a 300 MHz AMD K6 processor, 8 MB of flash memory, and 16 MB of dynamic random access memory (DRAM).
- The IS215UCVDH5AN is responsible for exchanging critical system data, including sensor readings (uploaded), control commands (downloaded), status updates, and alarm information (uploaded).
- The IS215UCVDH5AN connects to the Unified Data Highway (UDH) through an RJ-45 port,Acts as a link between this controller and other components and the centralized data hub.

Technical Specifications
| Parameter | Value |
|---|---|
| Model | IS215UCVDH5AN |
| System | Mark Vi |
|
Processor (CPU) |
AMD K6 |
|
Length |
286.78mm |
|
Width |
214.36mm |
|
Height |
188.263mm |
|
Weight |
1.28 kg |
Questions & Answers
💡 FAQ
How is this board installed?
+
-
It is not a standalone module. It plugs vertically into a dedicated termination board, model TTURH1C. All power, sensor signals, and communications are connected to this termination board via the connector on the back of the board.
What is the "Auto-Reconfiguration" feature? Why is it important?
+
-
Auto-Reconfiguration" is a critical feature. When a new PTUR board is installed and powered on, if this feature is enabled, it automatically downloads all necessary firmware, application programs, and configuration parameters from the Mark VIe controller.
What should pay attention to if replace the PTUR board?
+
-
The system must be in a safe state and follow the correct power-off and power-on procedures. Confirm that the model and version number (IS220PTURH1A) of the new board are exactly the same as the old board.
What could be the reason it reports "Sensor Failure"?
+
-
Possible causes include:
- The sensor itself is damaged.
- The sensor circuit is open (broken wire) or shorted.
- The gap between the sensor and the measuring gear is incorrect.
- The terminal blocks on the terminal board (TTURH1C) are loose.
How long is the warranty?
+
-
1 year

why choose us?
We specialize in providing industrial automation and control solutions, including ABB, GE, Bently Nevada, and other critical DCS/PLC components. Here's why customers trust us for their industrial automation needs:
one-stop solution
professional team
Quality Assurance
After-sales service




Contact us
Our address
Room 1904, Building B, Diamond Coast, No. 96 Lujiang Road, Siming District, Xiamen, Fujian, China
Phone Number
+86 18059275924
sales18@htechplc.com

Hot Tags: ge is215ucvdh5an processor controller board, ge is215ucvdh5an processor controller board manufacturers, suppliers, GE IS200TREGH1BDB, GE IS200TREGH1BDB Trip Emergency Termination Board, ge mark vi, IS200TREGH1BDB